Detailed Product Description

 1.CE
2.ISO
3.Certificate of conformity
4.Certificate of Free Sale

3-3 Specification
1 .Power Supply 220V±22V 5O±1Hz
2 .Power Consumption ≤450VA
3 .Air Temperature Control Range 25~37°C can override to 39°C
4 .Skin Temperature Control Range 30~37°C can override to 38°C
5. High Skin Temp Control Range 37.l~38°C
6. Uniformity of temperature ≤0.8°C
7. Temperature Precision ≤0.5°C(air temp.)
8. Over temp Alarm <38°C(air temp.)
9. Over temp Alarm(High temp Mode) <39°C(air temp.)
10. Air Temp Alarm +1.5°Cor -2.5°C(air temp.)
11. Skin Temp Alarm ±1 °C(air temp)
12. Sensor Precision ≤0.3°C
13. Noise Level ≤55dB(A)

STANDARD COMPOSITION:

1 Box temperature, skin temperature controlled by computer servo
2 Separately display set temperature, box temperature and skin temperature
3 over 37°C high temperature setting mode
4 Self-test alarm and acousto-optic prompt of over-heating, deviation, circulation, sensor, power outage
5 Adjustable baby bed tilt
6 Aluminous tank
7 Integral aluminum tank can be taken out for cleansing and disinfection
8 Protecting rail
9 RS-232 joint
10 Oxygen input joint
11 Streamline trilby
12 Optional blue-ray therapeutic apparatus, Special jaundice phototherapy lamp imported from Germany

Infant Incubator (YXK-5GB) (China)

Detailed Product Description 

infant incubator Double Walls Hood
 

1. Box temperature, skin temperature controlled by computer  
    servo; Instrument panel with backlight display
2. Self-detect function
3. Separately display set temperature, box temperature, skin
    temperature and humidity
4. >37 degrees high temperature setting mode
5. Self-test alarm and acousto-optic prompt of over-heating,
    deviation, circulation, sensor, power outage
6. Double walls hood, double door 

infinitely adjustable baby bed tilt
7. Integral aluminum tank can be taken out for cleansing and
    disinfection
8. Protection railing
9. RS-232 Connector
10. Oxygen input joint
11. Wind way humidified
12. Streamline trilby
13. Organic cover

Infant Incubator (YXK-2000G)
Double Walls Hood
(China)

Detailed Product Description 

infant incubator
1) bidirectional pull bed incubator
2) organic cover
3) self-test alarm

1. Box temperature, skin temperature controlled by computer servo; Instrument panel with backlight display
2. Self-detect function
3. Separately display set temperature, box temperature, skin temperature and humidity
4. >37 degrees high temperature setting mode
5. Self-test alarm and acousto-optic prompt of over-heating, deviation, circulation, sensor, power outage
6. infinitely adjustable baby bed tilt
7. Integral aluminum tank can be taken out for cleansing and disinfection
8. Protection railing
9. RS-232 joint
10. Oxygen input joint
11. Wind way humidified
12. Streamline trilby
13. Organic cover
Infant Incubator (YXK-7G) (China)

Detailed Product Description 
1.Air temp. servo-controlled by computer
2.Separate setting temp. and real temp. display windows

Medical device-Infant Incubator YXK-6G

1.Air temp. servo-controlled by computer
2.Separate setting temp. and real temp. display windows
3.Various and self-check alarms
4.Removable humidity trough,easy to clean
5.With the transfusion shelf and tray.



 
Infant Incubator (YXK-6G) (China)

BBP-400A (GLQ-2)(4tubs)
Detailed Product Description 
1. Available stand pole up-down adjustment
2. Available Angle adjustment 0° , 30° , 60°
3. Wave length : 400-500 um
4. Fit in with any infant bed and incubator
5. 4 Tubes or 5 tubes
Neonate Bilirubin Phototherapy  (China)

Detailed Product Description 
1:Adjustable height
2:Credible quality
3:CE/ISO/Certificate of conformity
4:Decades years manufacture experience


Main Use and Applicable Scope:

The product is applicable for the body temperature maintaining, emergency operation and intensive care of new-born baby, sick and weak infant and premature infant.

3.2 Normal Working Environment

a) Power voltage: (220±22)V (50±1)Hz;
b) Ambient temperature: 18~30°C, with the control temperature being at least 3°C higher than the ambient temperature

3.3 Product composition: temperature controller, radiation source, bed frame, spot light and frame, etc.

3.4 Heater: radiation-type far IR heating element.

3.5 Normal Working Environment:
a) Ambient temperature: 18~30°C, with the control temperature being at least 3°C higher than the ambient temperature;
b) Relative humidity: 30~75%;
c) Atmospheric pressure: 70~106Kpa;
d) Ambient air speed: < 0.3 m/s,
e) Placed in an arena with relatively static air flow and without direct sunlight and other heat sources.
f) Power voltage: 220±22V, 50±1Hz
g) Consumed power: ≤1000VA

3.6 Basic Parameters

1) Illumination of spot light at the bed center: ≥100lx
2) Constant temperature time: not less than 2h
3) Temperature uniformity: ±2°C with the baby bed at the horizontal level:

4)Temp-controlled mode:
Mode for infant temp-control: alarming when the temperature deviating by +1.5°C and -2.0°C after constant temperature is set.
Manual temp-control mode: the heater outputs at fixed energy level and at max output energy level.

5) Measuring range of skin temperature: 25.0°C~42.0°C
6) Setting range of skin temperature: 25.0°C~37.0°C
7) Operating time of manual temp-control: set as 15min

Infant Warmer (China)


Product characteristic:

The instrument only needs on the babies and infants forehead according to namely to take related observable lightly with the blood serum bilirubin value after the skin bilirubin value, avoided through drawing blood, the visual observation the ache which, the infection as well as the personal error brought to the baby, the simplicity of operator, carried conveniently.

Major technique target:
measurement mode: Light reflection type.
the measurement result showed: Three digital demonstrations.
flashing light working voltage directive function: The indicating lamp bright

expression may carry on the test.
hand reset function: After hand reset, three nixie tubes are dark. the duration of charging is short, after period of revolution long (sufficient electricity, may examine above 800 times).
electric power supply: The jaundice meter electric power supply for the nickel hydrogen battery, directs current 4.8V.
battery charger: Battery charger's electric power supply for the exchange 220V22V,50HZ1HZ, the battery charger outputs for the concurrent 6V1.2V, 56mA18mA, uses in this instrumentation specially the nickel hydrogen group charging
jaundice Meter (China)

 

Home  :  Products  :  Customers  :  Agents  :  Offers  :  Events  :  Services  :  Career  :  Contacts

Copyright ©  Star Med .net
Design and Developed By Graphicsgroup Co.
ستار ميد ( Star-med.net ) للتجهيزات الطبية الشاملة :: تجهيز المستشفيات بنظام تسليم المفتاح :: غرف العمليات :: العناية المركزة :: شبكات الغازات :: استقبال وطوارئ :: سونار :: مونيتور :: رسم قلب :: ترابيزة عمليات :: كشاف عمليات :: أجهزة تخدير انجليزى والمانى :: مناظير الجهاز الهضمى :: دياثرمى :: الات جراحية :: أثاث طبى Star med for Medical Suppliers & Equipments :: Hospital Equipments :: Operating Rooms :: ICU :: Pipes System :: Emergency :: Ultrasound :: Monitors :: ECG :: Operating Tables :: Operating Lights :: Anesthesia Machine :: Ventilators :: Endoscopy :: Diathermy :: Medical Furniture :: Medical Instruments